DATA PROGRAMMING
Assignment of FCH Related Data
Figure 5-29
shows a sample data assignment when FCH cards are located in the PIM 0 slot 4 and PIM 2 slot 11.
As an example, data assignment when FCH cards are accommodated in the following slots is shown here.
PIM 0, slot 4 and PIM 2, slot 11
FCH card
LENS 011190
PIM 2 Slot 11
LENS: 000270
PIM 0 Slot 04
PBX
Data Assignment
AFCH (Assignment of FCH Number for.....)
FCHN: 1 FCHEN: 00 0 27 0
FCHN: 2 FCHEN: 01 0 19 0
odd No.
Lv=0
The AFCH command display should look similar to the following:
Untitled - EclipseCmd
File View Help
AFCH (Assignment of FCCH Number for.....)
Before assigning FCHN, the trunk data must have been assigned using the ACTK command.
Note:
CHAPTER 5
Page 82
Revision 3.0
Use "odd number" as the Group No. and "Level 0" for the FCHN.
(Regular-density slot 04)
FCHN=2
Slot No.
Group No.
Bch (TK8)
FCHN=1
Bch (TK1)
FCH
Dch (TK2)
Use this LENS.
FCHEN
xx x 27 0
MG U Gr Lv

Figure 5-27 Assignment of FCH Number

FCHN
1
FCHNEN
000270
WRT?
Y

Figure 5-28 AFCH Command Display (example)

ND-70185 (E)
Get other manuals https://www.bkmanuals.com
example 1
DTI
04
05
01
03
Dch (TK1)
Bch (TK23)
Dch (TK2)
00
02
Use this LENS.
Bch (TK9)
27
FCHEN
xx x 19 0
Extended Group
MG U Gr Lv
FCH
example 2
(High-density slot 11)
DTI
Slot No.
11
12
Group No.
19
23
Dch (TK1)
Bch (TK23)
Bch (TK17)
22
Bch (TK16)
Bch (TK9)
21
Bch (TK8)
Bch (TK1)
20
FCHN (1-255)
FCHEN
x x x x x x
MG U Gr Lv
MG: 0-7
U: 0-3
Group: 00 - 31
Lv: 0-7