■ 5.9.2 Full Speed algorithm
This algorithm will set the fan speed duty cycle to 100%. In this situation, all fans will
run in full speed mode
■ 5.9.3 Performance algorithm
In this mode, BMC will set the fan duty cycle with table 5.9.1. Table 5.9.2 is showed
the mapping between fan duty cycle and fan speed.
Table 5.9.2: The mapping between fan duty cycle and fan speed
■ 5.9.4 Balanced algorithm
In this mode, BMC will set the fan duty cycle with table 5.9.3. Table 5.9.4 is showed the
mapping between fan duty cycle and fan speed.
CAR-5040 Series User's Manual
All manuals and user guides at all-guides.com
Table 5.9.1: The fan duty cycle rule of Performance mode
Duty cycle
30%
40%
50%
60%
70%
80%
100%
Duty cycle
30%
40%
50%
60%
70%
80%
100%
Table 5.9.3: The fan duty cycle rule of Balanced mode
Duty cycle
30%
40%
50%
60%
70%
CPU0 temperature
< 45
45
49
℃~
50
52
℃~
53
55
℃~
56
57
℃~
58
59
℃~
> 60
Fan speed
≒6556 rpm
≒8704 rpm
≒10368 rpm
≒12160 rpm
≒13696 rpm
≒14976 rpm
≒16640 rpm
CPU0 temperature
< 50
50
54
℃~
55
57
℃~
58
60
℃~
61
62
℃~