Chapter 2 Preparations
(1) Preparation before installing to the rack
We provide the four types of rails that are to be installed on the rack.
Also, the type of the rail is different depending on the drive model of 2.5-inch or 3.5-inch.
Check the following table for each model.
Model name
2.5-inch
drive model
3.5-inch
drive model
(a) Slide rail for 1U rack server N8143-131/132
Checking the inner and outer rails
Check the direction of the inner and outer rails.
Since there are markings of "Right" and "Left" on the outer rail, check the proper directions of right and left
with it. Likewise, check the directions of front and back with the markings of "Front" and "Rear."
On the inner rail, there is no marking for Front, Rear, Right or Left, so refer to the figure below to check the
each direction.
Right outer rail on front side
Left outer rail on front side
Front
168
N code
Part name
Extension rail for
N8143-127
1U rack server
Slide rail for
N8143-131
1U rack server
Extension rail for
N8143-128
1U rack server
Slide rail for
N8143-132
1U rack server
Important
Rail for left side has different shape from that for right side. Make sure the
orientation of rails to properly install them.
Outer rail
Right inner rail
Express5800/R120h-1M User's Guide
2. Installation and Connection
Specification
Ball bearing type rack rail for 2.5-inch drive
model (no inner rail used)
Slide rail type rack rail for 2.5-inch drive model
(inner rail used)
Ball bearing type rack rail for 3.5-inch drive
model (no inner rail used)
Slide rail type rack rail for 3.5-inch drive model
(inner rail used)
Left inner rail
Inner rail
Rear