*2 The power is not supplied, the power cord is not connected, the power supply unit is not installed, the
power supply unit is defect, or the power cord is disconnected.
*3 If the STATUS LED indicates a degraded or critical condition, check the system IML or use iLO to check
the system status.
・3.5-inch drive model
No.
1
UID switch/LED
2
LINK/ACT LED
3
STATUS LED
4
POWER Switch/LED
*1 If all the four LEDs described in this table is flashing at the same time, it indicates that a power failure has
occurred. For details, refer to (2) Power failure LED.
*2 The power is not supplied, the power cord is not connected, the power supply unit is not installed, the
power supply unit is defect, or the power cord is disconnected.
Item
*1
Lights in blue
Flashes in blue (once per
second)
Flashes in blue (4 times
per second)
Flashes in blue (8 times
per second)
Lights off
*1
Lights in green
Flashes in green (once per
second)
Lights off
*1
Lights in green
Flashes in green (once per
second)
Flashes in amber
Flashes in red (once per
second)
*1
Lights in green
Flashes in green (once per
second)
Lights in amber
Lights off
Express5800/R120h-1M User's Guide
Status
Working in operation
Remote management or firmware
upgrade is in progress
The iLO restart sequence using the UID
switch has been launched
The iLO restart sequence using UID
switch is in progress
Not working
Linked to the network
The network is working
The network is not working
Normal state
Restarting iLO
The function of the system is deteriorating
The system is in a critical state
The system is powered on
The power on sequence in progress
The system is in standby state
Power is not supplied