8.1

Error message "Emergency Stop was triggered"

To bring the charging station into a safe state immediately in case of danger, the charging
station can be equipped with an integrated Emergency Stop switch. If it is actuated, the
display of the charging station shows the following error message.
Figure 8-1  Error message "The emergency stop switch has been activated"
NOTE
Without an associated message at the charging station, it is not possible to differentiate
between interruption of the external safety loop and actuation of the Emergency Stop switch.
Emergency stop
As part of the emergency stop, the power supply of all charging outlets is switched off. Any
charging in progress is aborted immediately. The charging station switches to a safe state.
The control, communication with the operator and the touch screen remain active. The LEDs
light up red. In this state, operation of the charging station is no longer possible for safety
reasons.
Revoking the emergency stop
First eliminate the hazardous situation. Make sure that no vehicle is connected with the
charging station. If the emergency stop has been triggered by the emergency stop switch,
you can revoke the emergency stop via the emergency stop switch.