Maintenance Plan - Siemens SICHARGE D Operating Instructions Manual

Hide thumbs Also See for SICHARGE D:
Table of Contents

Advertisement

Maintenance and service

9.2 Maintenance plan

NOTE
Damage to property due to foreign objects inside the station
During maintenance work, foreign bodies such as dirt, tools or loose components may
remain in the charging station. This can result in a short-circuit, reduced cooling capacity or
increased running noise. The charging station may be damaged.
• During maintenance work, make sure that no foreign objects remain in and on the
charging station.
• Fasten loose parts again after maintenance work.
• Remove accumulated dirt.
9.2
Maintenance plan
The following maintenance measures are required to maintain the functionality and
operational safety of the charging station. You can find detailed instructions for replacement
of components in the document with order number 8EM5907‑0AA00‑4AA1.
Times of testing
After commissioning, carry out the checks at the following intervals:
• 6 months after commissioning
• 12 months after commissioning
After the first year, carry out the tests every 12 months. Perform the checks at shorter
intervals if necessitated by the ambient conditions of the SICHARGE D charging station (e.g.
high dust exposure).
Checking the charging station
For technical specifications, refer to the document with the order number
8EM5907-0AA00-7AA3 "Preventive Maintenance Checklist
(https://support.industry.siemens.com/cs/us/en/view/109814289)".
124
Operating Instructions, 11/2023, A5E50556539-AG
SICHARGE D

Advertisement

Table of Contents
loading

This manual is also suitable for:

8em5907-0aa00-1aa7.06

Table of Contents