HP 8110A Service Manual page 106

150 mhz pulse generator
Hide thumbs Also See for 8110A:
Table of Contents

Advertisement

D
elay
Scope Un certainty factor
TR Entr y
T est
L
imit
A
ctual
Limit
P
ass
F
ail
Minimum
R
esult
Maximum
4-1
0 .00 ns
Fi xed
D
elay
4-2
5.00 ns
3 .75 ns
6.25 ns
4 - 3
9.99 ns
8 .49 ns
11 .49 ns
4-4
50 .0 ns
46 .5 ns
53 .5 n s
4 - 5
99 .9 ns 93 .905 n s
105 .895 ns
4 - 6
100 ns
94 ns
106 ns
4 - 7
500 ns
474
n
s
526 ns
D
elay (con tinued)
Co un ter Un certainty factor
TR Entr y
T est
L
imit
Actual
Limit
Pass
Fail
Minimum
R
esult
Maximum
4-8
1 μs
949 ns
1051 ns
4 - 9
5 μs
4.749 μ s
5 .251 μs
4 - 10
50 μ s
47 .5 μ s
52 .5 μs
4 - 11
500 μ s
475 μs
525 μs
4 - 12
5
m
s
4.75
m
s
5.25
m
s
4 - 13
50 ms
47 .5
m
s
52 .5
m
s
4 - 14
500 ms
475
m
s
525
m
s
Testing the HP 811 0Α 3-59