Dell PowerEdge M420 Owner's Manual page 103

Dell poweredge m420 systems owner's manual
Hide thumbs Also See for PowerEdge M420:
Table of Contents

Advertisement

Error Code Message Information
SEL0006
Message
Details
Action
SEL0008
Message Log is full.
Details
When the event log is full, additional events are not written to the log. Older events may be
overwritten and lost. This message may also appear if the user disabled event logging.
Action
Backup and clear log.
SEL0010
Message Log is almost full.
Details
When the event log is full, additional events are not written to the log. Older events may be
overwritten and lost.
Action
Backup and clear log at the next maintained time.
SEL0012
Message Could not create or initialize the system event log.
Details
If the system event log fails to initialize, platform status and failure events are not captured.
Some management software do not report platform exceptions.
Action
Reboot the management controller or iDRAC. Cycle system input power. If problem persists
call support.
SEL1204
Message
LCD Message Unknown system hardware failure.
Details
Action
SEL1209
Message The platform event filter action failed.
Details
System policies or permissions may prevent the action from executing. If configured, the
system does not execute the action on a platform event (such as power down, cycle,
interrupt, and send alert).
Action
Review platform event configuration.
SEL1211
Message
Details
Action
SEL1300
Message No bootable media found.
All event logging is disabled.
This message is displayed when all event logging has been disabled by the user.
If unintended, re-enable logging.
An unknown system hardware failure detected.
If the system event log failed to initialize platform status and failure events are not
captured. Some management software will not report platform exceptions.
Re-configure system to minimum supported configuration. If issues persists, contact
support.
The time-stamp clock could not be synchronized.
The time stamp on system event log events may not correlate to the system time.
Cycle system input power. If problem persists, contact support.
103

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge m520Poweredge m820

Table of Contents