Error Code Message Information
Details
System setup displays the system boot order. The local video screen may also show
additional information. (IPMI sensor type code 1eh - offset 00h).
Action
Check system boot settings. Check if mass storage controller configuration settings are
applicable.
SEL1302
Message Non-bootable diskette detected.
Details
The disk in the drive is not formatted correctly or does not contain the necessary operating
system files.
Action
Replace diskette with a bootable disk.
SEL1304
Message
Details
Action
SEL1306
Message Invalid boot sector found.
Details
The disk in the drive is not formatted correctly or does not contain the necessary operating
system files.
Action
Replace diskette with a bootable disk.
SEL1308
Message A time-out occurred while waiting for user to select a boot source.
Details
The system has failed to boot to an operating system and needs the user to select a boot
source.
Action
Select boot source within the time allowed.
SEL1501
Message Chassis management controller (CMC) redundancy is lost.
Details
An action or failure has taken place that breaks CMC redundancy.
Action
Check the CMC network cables and network connections. Check that CMC firmware
versions match.
SEL1502
Message Chassis management controller (CMC) redundancy is degraded.
Details
An action or failure has taken place that breaks CMC redundancy.
Action
Check the CMC network cables and network connections. Check that CMC firmware
versions match.
SEL1504
Message The chassis management controller (CMC) is not redundant. Insufficient resources to
maintain normal operations.
Details
There is not enough available power for two CMC's to operate.
Action
Check the overall power consumption and power status.
104
The PXE server not found.
PXE is one way to boot a system from the network.
Check the network and PXE server configuration.