Dell PowerEdge M420 Owner's Manual page 98

Dell poweredge m420 systems owner's manual
Hide thumbs Also See for PowerEdge M420:
Table of Contents

Advertisement

Error Code Message Information
PWR1005
Message The system performance degraded because the user-defined power capacity has changed.
Details
The user-defined power settings have affected system operation.
Action
If unintended, review system configuration changes and power policy.
PWR1006
Message
LCD Message System power demand exceeds capacity. System halted.
Details
Action
PWR1007
Message
LCD Message System power exceeds capacity. Performance degraded. Check PSU configuration.
Details
Action
PWR1008
Message
LCD Message System power exceeds threshold. Performance degraded. Check PSU configuration.
Details
Action
RFM1003
Message
Details
Action
RFM1005
Message Removable Flash Media <
Details
The media is being prepared or is under maintenance. If the problem persists, reinstall the
card.
Action
Wait for the media to be ready.
RFM1006
Message Removable Flash Media <
Details
At boot, the Card Identification (CID) signature of the card is different from the Non-volatile
(NV) storage value or the card is the destination of a copy operation that is in-progress.
Action
If unintended, reinstall the flash media.
98
The system halted because system power exceeds capacity.
The system halted because system power exceeds capacity.
Review system configuration, upgrade power supplies or reduce system power
consumption.
The system performance degraded because power exceeds capacity.
The system is currently operating in a performance degraded state to attempt protect
from a power shutdown.
Review system configuration, upgrade power supplies or reduce system power
consumption.
The system performance degraded because power draw exceeds the power threshold.
The power threshold is configured by the user or automatically by software based on
system configuration.
Review system configuration, upgrade power supplies or reduce system power
consumption.
Removable Flash Media <
name > is not IPMI-function ready.
The removable flash media is installed but improperly configured or failed to initialize.
If unintended, reinstall the flash media and module.
name > is not ready.