Resetting a Unit on a Stack

Use the following reset commands to reload any of the member units or the standby in a stack. If you try to
reset the stack master, an error message is displayed:
Task
Reload a stack unit from the master switch
Reset a stack-unit when the unit is in a problem state.
Removing an Aggregator from a Stack and Restoring Quad
Mode
To remove an Aggregator from a stack and return the 40GbE stacking ports to 4x10GbE quad mode:
Step
Task
1
Disconnect the stacking cables from the unit. The unit can be powered on or off and can be online or offline..
2
Log on to the CLI and enter Global Configuration mode.
3
Configure the Aggregator to operate in standalone mode.
4
Log on to the CLI and reboot each switch, one after
another, in as short a time as possible.
When the reload completes, the base-module ports comes up in 4x10GbE (quad) mode. The switch
functions in standalone mode but retains the running and startup configuration that was last synchronized
by the master switch while it operated as a stack unit.
Reset of master unit is not allowed.
Command Syntax
reset stack-unit unit-number
reset stack-unit unit-number
hard
Command Syntax
Login: username
Password: *****
FTOS> enable
FTOS# configure
stack-unit 0 iom-mode
standalone
reload
Command Mode
EXEC Privilege
EXEC Privilege
Command Mode
---
CONFIGURATION
EXEC PRIVILEGE
Stacking | 211