Dell PowerEdge M IO Aggregator Command Reference Manual page 86

Mxl 10/40gbe switch io module ftos command reference guide, ftos 8.3.16.1
Hide thumbs Also See for PowerEdge M IO Aggregator:
Table of Contents

Advertisement

Table 6-3. show interface pfc summary Command Description
Remote is enabled, Priority list
Remote Willing Status is
enabled
Local is enabled
Operational status (local port)
PFC DCBX Oper status
State Machine Type
TLV Tx Status
PFC Link Delay
Application Priority TLV:
FCOE TLV Tx Status
Application Priority TLV:
ISCSI TLV Tx Status
Application Priority TLV:
Local FCOE Priority Map
Application Priority TLV:
Local ISCSI Priority Map
Application Priority TLV:
Remote FCOE Priority Map
Application Priority TLV:
Remote ISCSI Priority Map
PFC TLV Statistics:
Input TLV pkts
PFC TLV Statistics:
Output TLV pkts
PFC TLV Statistics:
Error pkts
PFC TLV Statistics:
Pause Tx pkts
PFC TLV Statistics:
Pause Rx pkts
72
|
Data Center Bridging (DCB)
Field
Operational status (enabled or disabled) of peer device for DCBX exchange of
PFC configuration with a list of the configured PFC priorities.
Willing status of peer device for DCBX exchange (Willing bit received in
PFC TLV): enabled or disabled.
DCBX operational status (enabled or disabled) with a list of the configured
PFC priorities.
Port state for current operational PFC configuration:
Init: Local PFC configuration parameters were exchanged with peer.
Recommend: Remote PFC configuration parameters were received from peer.
Internally propagated: PFC configuration parameters were received from
configuration source.
Operational status for exchange of PFC configuration on local port: match
(up) or mismatch (down).
Type of state machine used for DCBX exchanges of PFC parameters:
Feature - for legacy DCBX versions; Symmetric - for an IEEE version.
Status of PFC TLV advertisements: enabled or disabled.
Link delay (in quanta) used to pause specified priority traffic.
Status of FCoE advertisements in application priority TLVs from local DCBX
port: enabled or disabled.
Status of ISCSI advertisements in application priority TLVs from local DCBX
port: enabled or disabled.
Priority bitmap used by local DCBX port in FCoE advertisements in
application priority TLVs.
Priority bitmap used by local DCBX port in ISCSI advertisements in
application priority TLVs.
Priority bitmap received from the remote DCBX port in FCoE advertisements
in application priority TLVs.
Priority bitmap received from the remote DCBX port in iSCSI advertisements
in application priority TLVs.
Number of PFC TLVs received.
Number of PFC TLVs transmitted.
Number of PFC error packets received.
Number of PFC pause frames transmitted.
Number of PFC pause frames received
Description

Advertisement

Table of Contents
loading

Table of Contents