900 Series Programs

These programs are organized based on functions versus program numbers.

System Initialize

This program enables you to reset hardware and initializes, or restores programmed data.
Program Number(s): 900
Prerequisite Program:
Reference:
Access Sequence:
FB Name
Initialize Level
01
To access programming parameters
FB01
1. Press
to choose Initialize Level 1 or 2.
Hold
2. Press
twice to initialize.
Choosing Initialize Level 1 without installing a SmartMedia Card deletes all
Important!
programmed data and returns your Strata CTX to factory default settings. All
previously programmed data is lost.
Restoring Data from SmartMedia
When initializing with Level 1 you can restore custom data that was previously programmed and stored on
a SmartMedia card. To do so, follow the steps below.
1. Install a SmartMedia card that contains the Prgdata directory with the default.dat file. The
default.dat file contains your custom settings and can be created by running Data Backup. See
ìData Backupî
A CTX
Important!
is the same or higher than the CTX software version on which the default.dat file
was created.
Examples: A
MF030, MF031 and higher R2.1MG0XX, R2.2 MF0XX (XX = 01~99, but it cannot
be restored on R2.0 MF012, MF011 and lower, or R1.X ME0XX, MD0XX, etc.
2. After installing the SmartMedia card, run System Initialization using Initialize Level 1.
Restoring data from the SmartMedia card may take an hour or more. To verify completion of the restore
process access, the Programming Mode from a telephone and enter your password. If the system
enables you to continue, the data restore process is complete.
Note During the restore process, the telephone LCD may display date and time data. This does not
necessarily indicate completion of the restore process.
Strata CIX/CTX Telephone Button Programming 11/04
None
None
Login to programming mode from your telephone button pad:
Hold ✱#✱#1✱2✱3✱ .
At the PASSWORD= prompt, Enter your password and press Hold .
At the PROG= prompt enter 900 and press Hold .
FB
Summary
Press 1 or 2 to select the initialize level.
Level 1 ñ Erases programmed data and
enters default data or backed up data if a
SmartMedia Card is installed (see Note).
Level 2 ñ Simulates System Power Off/Power
On operation to reset hardware.
on
page
1-106.
default.dat
database can only be restored to a CTX software version that
default.dat
1. Initialize Level 1
2. Initialize Level 2
created on CTXR2.0 MF029 can be restored on an R2.0
Telephone Button Programming
900 Series Programs
Value
LCD Prompt
1:Restart with
Clear Data
2:Restart