Toshiba Strata CIX Programming Manual page 92

Telephone button programming manual
Hide thumbs Also See for Strata CIX:
Table of Contents

Advertisement

Telephone Button Programming
500 Series Programs
Table 1-35
Programs 500~577 (continued)
Button
Sequence
570
Account Code Digit
Length
570
Hold
,
570-01
Verified Digit Length
FB01
Hold
, n,
570-02
Registered Digit
Length
FB02
Hold
, n,
571
Exception Numbers
for Forced Account
Codes
571
Hold
,
571-01
Exception Number 1
FB01
Hold
, n,
571-02
Exception Number 2
FB02
Hold
, n,
571-03
Exception Number 3
FB03
Hold
, n,
571-04
Exception Number 4
FB04
Hold
, n,
573
Delete Door Phone
573
Hold
,
573-00
Door Phone
Hold
Hold
n,
,
576
Door Phone Night
Ring Over External
Page
576
Hold
,
576-00
Tenant Number
Hold
n,
576-01
Page Group Number
FB01
Hold
, n,
577
Caller History
577
Hold
,
577-00
Circuit Type/Number
Hold
n,
577-01
Primary DN
FB01
Hold
, n,
1-88
Value(s)
n =
4~15
(default = 4)
n =
4~15
(default = 6)
Hold
,
n =
Up to 4 digits
Exception 1 default = 911
Exception 2~4 default = no
value
Hold
,
n =
1~6 (CTX100)
1~9 (CTX670 Basic)
1~24 (CTX670 Exp.)
n =
1~2 (CTX100)
1~8 (CTX670)
n =
0~4 (CTX100)
0~8 (CTX670 Basic)
Hold
,
0~16 (CTX670 Exp.)
(default = 0)
n =
Up to 6 digits
n =
Up to 5 digits
Hold
,
Summary
Accounting Codes need to be specified for the number of digits that
are expected to be used for registering a number. This allows dialing
within Strata CTX to proceed automatically once the correct account
code is dialed. The following numbers are then dialed digits used for
making the phone call.
A second length is provided to allow the number of digits to be used
for verification of the code to be less than the total code entered; thus,
the code may contain two parts, one required and one part optional to
the user..
The Verified Digit Length sets a number of digits to verify with a pre-
set list. This number may be the same or smaller than the account
code digits set to be entered for creating a complete accounting code.
Note
This field is not changed, when
are registered.
The Registered Digit Length sets a number for the digits to be entered
to make a complete accounting code entry.
Note
The Registered Digit Length (
equal to the Verified Digit Length (
Up to four telephone numbers can be programmed as exceptions to
the forced and /or verified account code entries (including 911).
These special codes enable numbers to bypass the verification
process and proceed unhindered.
Enter a Forced Account Code Exception.
Note
One of the assigned exception numbers should be 911.
Exception Numbers for Forced Account Code fields cannot
be duplicated.
This command deletes door phone.
Enter the number of the door phone that is to deleted.
This command assigns a Page Group to ring during system Night
Mode when a door phone button is pressed. The assignment can be
made independently for each Tenant.
Select the system Tenant number to be assigned Door Phone to Page
Group/Night Ringing.
Select the system Page Group number that should ring for the
selected Tenant when a door phone button is pressed during the
system Night Mode.
This command assigns which station stores Caller ID information for
PDN,CO,GCO and POOL line buttons
Enter the Circuit Type and number. See the
Enter Station DN to store call history data.
Strata CIX/CTX Telephone Button Programming 11/04
ìProgram 506î on page 75
FB02
) must be greater than or
FB01
).
Table 1-36
on
page
89.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata ctxStrata ctx28Strata ctx100Strata ctx670

Table of Contents