Removal Of Bioclip Plug; Replacing Mowing Deck Belts; Belt Replacement On Bioclip 90 - Husqvarna Rider 15V2 Workshop Manual

Hide thumbs Also See for Rider 15V2:
Table of Contents

Advertisement

For Husqvarna Parts Call 606-678-9623 or 606-561-4983
Reparation instructions
Removing the BioClip Plug (Combi)
To change a Combi unit from the BioClip function to
a cutting unit with rear ejection, remove the BioClip
plug, which is located under the unit, attached with
three screws.
1. Put the unit in the service position, see 'Placing
in the Service Position'.
2. Remove the three screws holding the BioClip
plug and remove the plug.
3. Tip: Fit three full-thread screws M8x15 mm in
the screw holes to protect the threads.
4. Return the unit to the normal position.
Fit the BioClip plug in the reverse order.
Replacing the Cutting Unit's Belts

Belt replacement on BioClip 90

BioClip 90 is powered by a toothed drive belt that
synchronises the rotation of the blades. The belt is
located under the cutting unit cover.
1. Dismantle the cutting unit.
2. Loosen the front bolt on the parallel strut and
swing back the strut. Swing the height
adjustment strut forwards.
3. Remove the screws holding the protective
cover and lift off.
WARNING!
Protect your hands with gloves
when working with the blades.
4. Tip: Mark the position of the blades on
respective belts with a felt tipped pen.
Loosen the nut on the eccentric plate and twist
this round. Loosen the four nuts (see picture)
holding the blade bearing, so much that the
bearing can be moved. Slide the blade bearing
inwards and pull off the belt.
56
– English
www.mymowerparts.com