9.11.7 Panel PCB ASSY / Rubber Key R/C/L

(1) Release the Hooks of the Panel unit, and remove the Panel PCB ASSY from the Panel
unit.
(2) Remove the Rubber key R/C/L from the Panel unit.
(3) Remove the Panel insulation sheet from the Panel unit.
Panel PCB ASSY
Rubber key L
Rubber key C
Rubber key R
Hooks
Hooks
Panel unit
Panel insulation sheet
Fig. 5-176