4. Connect the range to the gas supply.

To prevent leaks, put a pipe joint sealant on all male
(outside) pipe threads. The regulator is in the location
shown below.
Do not allow regulator to turn on
pipe when tightening fittings.
a) Install an external manual gas shut-off valve to
gas supply line in an easily-accessible location
outside of the range. Be sure you know how and
where to shut-off the gas supply to the range.
b) Attach appliance conduit to flare union on
regulator.
c) Attach appliance conduit to the flare union on
the regulator.
d) Install flare union adapter to external manual
shut-off valve.
e) Attach appliance conduit to flare union on shut-
off valve.
f)
Make sure service shut-off valve on pressure
regulator is in "ON" position.
g) Check for leaks. Turn the gas supply on to the
range and use a liquid leak detector at all joints
and conduits to check for leaks in the system.
Do not use a flame to check for gas
leaks.

Checking Manifold Gas Pressure

See page 23.
5. Read electrical connection details below and
connect electricity to range.
Before servicing, disconnect
electrical supply at circuit breaker, fuse or power
cord.
Electric Requirements:
An individual, properly grounded and polarized branch
circuit protected by a 15 amp. circuit breaker or time
delay fuse. See serial plate for proper voltage.
Extension Cord Precautions:
Because of potential safety hazards under certain
conditions, we strongly recommend against the use of
any extension cord. However, if you still elect to use an
extension cord, it is absolutely necessary that it be a UL
listed 3-wire grounding type appliance extension cord
and that the current carrying rating of the cord in amperes
be equivalent to or greater than the branch circuit rating.
Such extension cords are obtainable through your local
service organization.
PLEASE READ CAREFULLY! For
personal safety, this product must be properly
grounded.

Grounding Instructions:

The power cord of this appliance is equipped with a
3-prong (grounding) plug which mates with a standard
3-prong grounding wall receptacle to minimize the
possibility of electric shock hazard from this appliance.
The customer should have the wall receptacle and
circuit checked by a qualified electrician to make sure
the receptacle is properly grounded and polarized.
Where a standard two-prong wall receptacle is
encountered, it is the personal responsibility and
obligation of the customer to have it replaced with a
properly grounded three-prong wall receptacle.