B. Surface Burner Valves Conversion
Top Burner Adjustment
Figure 9
1. Lift cooktop to gain access to the surface
burner spuds.
2. With ½" wrench, turn spud down or clockwise
until snug (approximately 2 ½ turns). This re-
stricts the flow of gas through spud to that al-
lowed only by the hollow LP metering pin. Do
not overtighten.
Pin
Natural Gas
Increase Gas
Increase Flame
Size
(Pre-Set at Factory
for Natural Gas)
Figure 10
3.Lower main top and apply gas to check for proper flame
NA T .
Inner Cone Flame Length
Cap Screw
Air Shutter
C. Readjust the "LOW" Setting Surface Burner
Nat.
Hood
L . P .
Pin
D. Air Adjustment Shutter
Spud

Air adjustment shutter

L.P. Gas
Decrease Gas
Decrease Flame
Size
30
size. Flame should be steady with approximately ½"
blue inner cones and no yellow or orange tips.
Figure 11
Proper Air Adjustment
If air shutter is adjusted so that too much air flows
into the burner, the flame will appear unsteady,
possibly not burning all the way around and will be
noisy (like a blow torch).
Valve
1. Turn control to LITE until burner ignites.
2. Quickly turn knob down to LOWEST SETTING.
3. If burner goes out, readjust valve as described
in "Adjust the LOW Setting Surface Burner
Valve" from Page .
Apply gas to the burner and adjust air shutter on
burner venturi tube to proper flame. For LP gas,
the air shutter is generally left completely open.
Figure 12
The air adjustment for each burner is located at
the open end of the venturi tube and sits on the
hood of the valve. The shutter is held in place by
friction fit.
½"