Converting The Oven And Broil Burners; Reconnect Gas And Electric Supply To Range - Electrolux Next Gen 30" Service Manual

Freestanding
Hide thumbs Also See for Next Gen 30":
Table of Contents

Advertisement

3. Convert Oven Burner Orifice for LP/Propane
Gas (16,000 BTU*)
a. Locate the oven burner spud (See Figure 8).
b. Using a 1/2" wrench, turn down the adjustable spud,
which injects gas into the oven burner, until snug
against the LP/Propane metering pin (approximately
2-1/2 turns). Do not over tighten.
4. Convert Waist-High Broiler Burner Orifice Flame
for LP/Propane Gas (13,500 BTU*) —Self-Cleaning
Models Only
a. Open the oven door.
b. Locate the broiler burner spud and turn down until
snug against the LP/Propane metering pin
(approximately 2-1/2 turns). Do not over tighten
(See Figure 8).
5. Reconnect Gas and Electrical Supply to
Range.
Leak testing of the appliance shall be conducted according
to the Installation Instructions provided with the Range.
Figure 8
Checking Manifold Gas Pressure
If it should be necessary to check the manifold gas
pressure, remove the burner cap and connect a
manometer (water gauge) or other pressure device to the
top right front burner orifice. Using a rubber hose with
inside diameter of approximately 1/4," hold tubing down
tight over orifice. Turn burner valve on. For an accurate
pressure check, have at least two (2) other surface
burners burning. Be sure the gas supply (inlet) pressure
is at least one inch above specified range manifold
pressure. The gas supply pressure should never be over
14" water column. When properly adjusted the manifold
water column pressure is 10" for LP/Propane gas or 4"
for Natural gas.
Do not use a flame to check for gas
leaks.
a. Disconnect the range and its individual shut-off valve
from the gas supply piping system during any
pressure testing of that system at test pressures
greater than 14" of water column pressure
(approximately 1/2" psig).
b. The appliance must be isolated from the gas supply
piping system by closing its individual manual shut-
off valve during any pressure testing of the gas
supply piping system at test pressures equal to or
less than 14" of water column pressure (approximately
1/2" psig).
To
Surface
Burner
Test to verify if "LOW" setting should be adjusted:
a. Push in and turn control to LITE until burner ignites.
b. Push in and quickly turn knob to LOWEST POSITION.
c. If burner goes out, reset control to OFF.
d. Remove the surface burner control knob.
e. Insert a thin-bladed screwdriver into the hollow valve
stem and engage the slotted screw inside. Flame
size can be increased or decreased with the turn of
the screw. Turn counterclockwise to increase flame
size. Turn clockwise to decrease flame size. (See
Figures 9 and 10).
Adjust flame until you can quickly turn knob from LITE to
LOWEST POSITION without extinguishing the flame.
Flame should be as small as possible without going out.
23