Program
Program Name
Number
84-26-02
IPL Basic Setup – RTP Port
Number
84-26-03
IPL Basic Setup – RTCP Port
Number (RTP Port Number + 1)
90-10-01
System Alarm Setup – Alarm
Type
Operation
None
2 - 736
Description/Comments
Define the TCP port number for
RTP to use for each DSP.
Only even numbered ports
are supported.
Define the TCP port number for
RTCP to use for each DSP.
Define if Alarms are Minor, Major,
or Not Set.
IP Trunk – (SIP) Session Initiation Protocol
UNIVERGE SV8100
Assigned Data
1
0~65534
Defaults:
VoIP GW1 = 10020
VoIP GW2 = 10052
VoIP GW3 = 10084
VoIP GW4 = 10116
VoIP GW5 = 10148
VoIP GW6 = 10180
VoIP GW7 = 10212
VoIP GW8 = 10244
0~65534
Defaults:
VoIP GW1 = 10021
VoIP GW2 = 10053
VoIP GW3 = 10085
VoIP GW4 = 10117
VoIP GW5 = 10149
VoIP GW6 = 10181
VoIP GW7 = 10213
VoIP GW8 = 10245
0 = Not Set
1 = Major Alarm
2 = Minor Alarm
(default not assigned)