Issue 5.0
System IP Phones and Analog Trunks
NEC does not recommend using IP Phones with analog trunks. Due to the nature of analog-to-digital
conversion, considerable echo is created which cannot be removed by the UNIVERGE SV8100 echo
canceller. Digital (ISDN) trunks do not suffer from this problem.
For outgoing calls:
Verify no analog trunk ports exist (CD-4COTB or CD-4ODTA) in the trunk routes (Program 21-02).
For incoming calls:
Ensure there are no IP Phones in the trunk targets (Program22-04 and 22-07).
For transferred calls:
It is impossible to stop an analog trunk call being transferred to an IP Phone. It is important that the
end-user is made aware of this limitation.
Conditions
The voice quality of VoIP depends on variables such as available bandwidth, network
latency and Quality of Service (QoS) initiatives, all of which are controlled by the network
and Internet service providers. Because these variables are not under its control, NEC
cannot guarantee the performance of the user's IP-based remote voice solution. Therefore,
NEC recommends connecting VoIP equipment through a local area network using a Private
IP address.
IP Multiline Stations must register with the IP address of the IPLA. The IP Multiline stations
registering via a URL is not supported.
If an internal paging group has only IP Multiline Stations, mutlicast is used for the page. IP
multiline terminals must have a gateway programmed to accomplish a multicast
transmission. When an actual gateway device does not exist on the network, a dummy
gateway address on the same subnet must be defined. If the paging group has any TDM
stations or an external speaker, multicast is not used and the gateway is not required.
The system sees terminal types 1 (Economy), 2 (Value), 3 (Desi-Less), 4 (Sophisticated)
and 5 (Softphone) as the same terminal type.
When using Multiple Logon, the same Personal ID index can be assigned to an
ITL/Softphone, a CTI (Desktop), and an MH240 terminal type.
Two ports of the same terminal type (Program 15-05-26) cannot be assigned to the same
Personal ID index (Program 15-05-27).
Program 10-46-01 must be set to 1 (Auto) or 2 (Manual) for Multiple Logon to work.
When three ports are assigned the same Personal ID index in Program 15-05-27, if
Program 15-05-26 is not set for those ports, the terminal types will be assigned based on
order of login. If Program 15-05-26 is set, the login order does not matter and they will
assign the correct port.