Error Code
Message Information
Action
CPU0000
Message
Details
Action
CPU0001
Message
Details
Action
CPU0005
Message
Details
Action
CPU0010
Message
Details
Action
CPU0023
Message
Action
CPU0204
Message
Details
Action
Check system fans. If the problem persists, see
CPU <number> has an internal error (IERR).
System Event Log and Operating System Logs may indicate
that the exception is external to the processor.
Review System Event Log and Operating System Logs. If the
issue persists, see
Getting
CPU <number> has a thermal trip (over-temperature) event.
The processor temperature increased beyond the
operational range.
Review the logs for fan failures. If no fan failures are
detected, check inlet temperature (if available) and reinstall
processor heat sink. If the problem persists, see
CPU <number> configuration is unsupported.
System is unable to boot or may run in a degraded state.
Review the technical specifications for supported processor
types.
CPU <number> is throttled.
The CPU is throttled due to thermal or power conditions.
Review system logs for power or thermal exceptions.
CPU <number> is absent.
Verify processor installation. If present, re-seat the
processor.
CPU <number> <name> voltage is outside of range.
Voltages outside the allowable range may damage electrical
components or may cause the system to shutdown.
1.
Turn off the system and remove input power for one
minute.
2.
Ensure the processor is seated correctly.
3.
Reapply input power and turn on the system.
4.
If the issue persists, see
Getting
Help.
Getting
Getting
Help.
Help.
Help.