Error Code
Message Information
Action
PSU1204
Message
Details
Action
PWR1004
Message
Details
Action
PWR1005
Message
Details
Action
PWR1006
Message
Details
Action
RFM1008
Message
Details
Action
RFM1014
Message
96
Check input power. Reinstall the power supply. If the issue
persists, see
Getting
Help.
The power supplies are not redundant. Insufficient resources
to maintain normal operations.
The current power operational mode is non-redundant
because of a power supply exception, a power supply
inventory change, or a system power inventory change.
Check the event log for power supply failures. Review
system configuration and power consumption.
The system performance degraded because power capacity
has changed.
The system may power down or operate in a performance
degraded state.
Check the event log for power supply failures. Review
system configuration and power consumption and upgrade
or install power supplies accordingly.
The system performance degraded because the user-
defined power capacity has changed.
The user-defined power settings have affected system
operation.
If unintended, review system configuration changes and
power policy.
The system halted because system power exceeds capacity.
The system halted because system power exceeds capacity.
Review system configuration, upgrade power supplies or
reduce system power consumption.
Failure detected on Removable Flash Media <name>.
An error was reported during a SD card read or write.
Reseat the flash media. If the problem persists, see
Help.
Removable Flash Media <name> is write protected.
Getting