On-screen error message
0B82
BMC Core hardware failed.
BMC IBF or OBF check
0B83
failed.
0B8A
BMC SEL area full
Recommended action
1. Press the POWER switch of EcoPowerGateway to turn
off the power, then turn it on.
2. If the same error persists, contact your service
representative.
1. Take one of the following measures to reboot (reset)
the maintenance card.
* Press Ctrl + Alt + Del.
* Issue a command from Web browser of
EXPRESSSCOPE Engine 2 or NEC ESMPRO
Manager.
2. Take one of the following measures to power off the
maintenance card and then on.
* Press the Maintenance switch to power off the
maintenance card, then press it again to power on.
* Issue a command from Web browser of
EXPRESSSCOPE Engine 2 or NEC ESMPRO
Manager.
3. If the same error persists, contact your service
representative.
1. Run BIOS SETUP, select [Server] - [Event Log
Configuration] - [Clear All Error Logs] to clear the IPMI
system event logs.
2. If the same error persists, contact your service
representative.
Note: You can make a backup copy of IPMI system event
logs through the Off-line Maintenance Utility before
clearing the IPMI system event logs on BIOS
SETUP.
Troubleshooting 6-7