NEC EcoPowerGateway N8142-36F User Manual page 87

Table of Contents

Advertisement

Server
The items which can be set on the Server menu and their functions are described below.
For setting of [System Management], [Console Redirection], [BMC LAN Configuration], and
[Event Log Configuration], first select the item and press Enter to display the submenu.
Option
Parameter
System
N/A
Management
Console
N/A
Redirection
BMC LAN
N/A
Configuration
BMC
N/A
Configuration
Event Log
N/A
Configuration
Assert NMI on
Disabled
PERR
[Enabled]
Assert NMI on
Disabled
SERR
[Enabled]
FRB-2 Policy
Disable FRB2
Timer
[Retry 3 Times]
Always Reset
Boot Monitoring
[Disabled]
5 minutes
10 minutes
15 minutes
20 minutes
25 minutes
30 minutes
35 minutes
40 minutes
45 minutes
50 minutes
55 minutes
60 minutes
Boot Monitoring
[Retry 3 Times]
Policy
Always Reset
Configuring Your EcoPowerGateway 4-17
Description
When enabled, PCI bus parity error (PERR)
can be detected and notified as NMI at
occurrence of an error.
When enabled, PCI bus system error (SERR)
can be detected and notified as NMI at
occurrence of an error.
Set the policy to be applied to FRB level 2
timer at occurrence of an error..
Specify whether the boot monitoring feature
is enabled or disabled and the timer value on
booting.
Set this item to "Disabled" because the
EcoPowerGateway does not support the
NEC ESMPRO Agent.
This item indicates the processing at the
occurrence of timeout during boot monitoring.
Retry 3 times: The system is reset after the
occurrence of timeout and OS boot is
retried up to three times.
Always Reset: The system is reset after the
occurrence of timeout and OS boot is
retried repeatedly.
Your Setting

Advertisement

Table of Contents
loading

Table of Contents