Key Product Safety Areas; Flamepath Dimensional Requirements - ABB Endura AZ30 series Programming Manual

Integral probe and remote transmitter combustion oxygen monitor
Hide thumbs Also See for Endura AZ30 series:
Table of Contents

Advertisement

Endura AZ30 series integral probe and remote transmitter
Combustion oxygen monitor

2 Key Product Safety Areas

Warning. Before installation and / or maintenance refer to Fig.2.1, page 9 to familiarize yourself with:
Mains power.
Hot surfaces.
Flamepath types and locations (surface finishes, thread lengths, threadforms and fits on all
flamepaths must remain undamaged to maintain system integrity and Hazardous Area
certification).
Locking screw locations (locking screws must be in the
operational. Use the 3 mm A/F hexagon wrench [supplied]).

2.1 Flamepath Dimensional Requirements

For dimensional checking purposes, Table 2.1 gives the values and tolerance of the spigot-type joints in the
probe's construction – refer to Fig. 2.1, page 9 for flamepath FP
Flamepath ID
2
FP
A
2
FP
B
Table 2.1 Flamepath Dimensions Outside of the Requirements of IEC60079–1 for Inspection and Maintenance
8
Spigot OD mm (in.)
+0.03 (+0.00118)
44.0 (1.732)
–0.015
(–0.00059)
+0.03 (+0.00118)
31.96 (1.258)
–0.015
(–0.00059)
2 Key Product Safety Areas
position at all times the system is
locked
2
2
A and FP
B locations.
Bore ID mm (in.)
44.0 (1.732)
32.0 (1.259)
COI/AZ30E–EN Rev. D
+0.05 (+0.00196)
–0.35
(–0.01377)
+0.04 (+0.00157)
–0.00
(–0.0)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents