Siemens SINUMERIK 828D Function Manual page 45

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

Canceling follow­up mode
Once follow-up mode has been canceled, the machine axis does not have to be homed again if the maximum
permissible encoder limit frequency of the active measuring system was not exceeded during follow-up mode. If
the encoder limit frequency is exceeded, the controller will detect this:
DB31, ... DBX60.4 / 60.5 = 0 (homed/synchronized 1 / 2)
Alarm: "21610 Encoder frequency exceeded"
Note
If "follow-up mode" is deactivated for a machine axis, which is part of an active
transformation (e.g. TRANSMIT), this can generate movements as part of repositioning
(REPOS) other machine axes involved in the transformation.
Monitoring
If a machine axis is in follow-up mode, the following monitoring mechanisms will not act:
Zero-speed monitoring
Clamping monitoring
Positioning monitoring
Effects on other interface signals:
DB31, ... DBX60.7 = 0 (position reached with exact stop fine)
DB31, ... DBX60.6 = 0 (position reached with exact stop coarse)
DB31, ... DBX1.5 / 1.6 (position measuring system 1 / 2)
2 measuring systems can be connected to one machine axis, e.g.
Indirect motor measuring system
Direct measuring system on load
Only one measuring system can be active at any one time. All closed-loop control, positioning operations, etc.
involving the machine axis always relate to the active measuring system.
Figure 1-4
Position measuring systems 1 and 2
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
A2: Various NC/PLC interface signals and functions
1.2 NC/PLC interface signals
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840d sl

Table of Contents