Mode Group Stop - Siemens SINUMERIK 828D Function Manual

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

K1: Mode group, channel, program operation, reset response
9.2 Mode group (MG)
Machine data
There are no mode group­specific machine data.
Channel gaps
The channels to which a mode group is assigned with MD10010 are regarded as activated.
Instead of a mode group number, the number "0" can be assigned to channels. The result is as follows:
The non­activated channel does not take up memory space in the control.
Series machines with similar designs can be kept uniform during configuration. Only the channels that can
actually be used by the machine tool are activated (channels with mode group number greater than 0).
Special case:
Channel 1 must always be available!
⇒ If:
MD10010 $MN_ASSIGN_CHAN_TO_MODE_GROUP [0] = 0
is specified, the control automatically sets
MD10010 $MN_ASSIGN_CHAN_TO_MODE_GROUP [0] = 1 (mode group 1).
Example configurations:
MD10010 $MN_ASSIGN_CHAN_TO_MODE_GROUP[0] = 1
MD10010 $MN_ASSIGN_CHAN_TO_MODE_GROUP[1] = 2
...
MD10010 $MN_ASSIGN_CHAN_TO_MODE_GROUP[3] = 0 ; gap
...
MD10010 $MN_ASSIGN_CHAN_TO_MODE_GROUP[8] = 1
MD10010 $MN_ASSIGN_CHAN_TO_MODE_GROUP[9] = 2
9.2.1

Mode group Stop

Function
The following NC/PLC interface signals are used to stop the traversing motions of the axes or of the axes and
spindles in all mode group channels and to interrupt part program execution:
DB11 DBX0.5 (mode group Stop)
DB11 DBX0.6 (mode group Stop axes plus spindles)
482
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Basic Functions

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840d sl

Table of Contents