Hitachi IJ RX2 Technical Manual page 50

Ink jet printer for industrial marking
Hide thumbs Also See for IJ RX2:
Table of Contents

Advertisement

●No-contact (transistor)
Withstand voltage
Maximum drive current
Residual voltage
Leakage current
Drive method
Contact signal
Use a relay whose contacts chattering at contacts ON/OFF is 2.0ms or less.
4.3.3-1 Print stop signal input
[Function] This function prevents printing from the outside. (Note that the Ready to print output signal does not
change even if this signal is input from the outside.)
Input ON
- In the IJ printer Ready to print state, the printer does not print even if the product target
detector is turned ON. However, the product being printed cannot be aborted.
Input OFF - In the IJ printer Ready to print state, the printer prints when the product target detector is
turned ON.
Print stop signal
Print target detector
Printing-in-progress signal
Printing operation
●Regarding the signal levels, the ON state indicates low level and the OFF state indicates high level.
●The tracking function cannot be used.
In the tracking mode, the timing which stops printing by print stop signal cannot be specified.
●When Repeat print is set, the IJ printer is controlled by a print start signal generated internally.
4.3.3-2 Reciprocative print signal input
[Function] This function switches the order of the characters to be printed.
Input OFF : Forward direction
Input ON : Reverse direction
Reciprocative print signal
Product target detection signal
*When the user environment setup item "Change Character Orientation" was set to "Reverse direction
printing", provide a minimum interval of 100ms up to input of the print target detector signal after
changeover (ON→OFF, OFF→ON) of the reciprocative printing signal.
When the Change Character Orientation was set to "normal or inverted" or "Character orientation 0 or
3", provide a minimum interval of 400ms up to input of the print target detector signal after signal
changeover.
4-19 ●Input/output (I/O) specifications
: 30VDC or greater
: 6mA or greater
: 2V or less
: 0.1mA or less
: Open collector
OFF
ON
0ms or
50ms or greater
greater
OFF
ON
OFF
ON
Printing
(Example)
When OFF
1 2 3         
ON
OFF
OFF
20ms or greater
50ms or greater
[No printing]
When ON
1 2 3  (The arrow indicates
ON
ON
Min. 100ms
Min. 100ms
50ms or greater
Printing
the sequence of printing. )

Hide quick links: