(2) Output signals (IJ printer →external device)
No.
Signal name
1 Ready
2 Fault
3 Warning
Print. in
Progress *4)
4
Print.
Completed *4)
5 Online output
*4): As regards "Print. in progress" and "Print. completed", one must be selected from a screen.

4.3.1 Print target detector input

This function inputs the IJ printer print start signal.
Use a no-contact (transistor) type print target detector. An optoelectronic sensor with built-in amplifier
which uses a light beam to detect the print target is ideal. When the total current consumption of the print
target detector and the rotary encoder is 100mA or less, power can be supplied from the power supply
built into the IJ printer. When the total current consumption exceeds 100mA, provide a dedicated power
supply.
In this case, perform wiring and setting as described below.
(1) Print target detector connection method
(a) When NPN interface and IJ printer built-in
power supply are used
Print target detector
SW1 setting
ON
1
2
4-9 ●Input/output (I/O) specifications
Operates when the IJ printer is ready for
printing or in input mode.
Operates when the IJ printer is fault state.
Operates when the IJ printer is in alarm
condition.
Operates when the IJ printer is engaged in
printing.
Operates when the IJ printer completes a
printing process
(outputs a pulse of up to 1 second).
Operates when the IJ printer is in online
mode
TB1
Power
1
Signal
2
GND
3
4
・SW1 "3": ON
・SW1 "5": ON
・SW1 "6": OFF
3
4
5
6
7
8
Function
(b) When PNP interface and IJ printer built-in
power supply are used
DC24V
Signal
GND
NC
Print target detector
SW1 setting
ON
ON
1
2
OFF
Electrical characteristics
Open collector (NPN)
● Sink current: 20 mA max.
● ON voltage: 0.5 V or less
● Operating voltage: 30 V or less
Open collector (NPN)
● ON voltage:
0.5 V or less
● Sink current:
20 mA max.
● Operating voltage:
30 V or less
TB1
Power
1
Signal
2
GND
3
4
・SW1 "3": OFF
・SW1 "5": ON
・SW1 "6": ON
3
4
5
6
7
8
Open collector (PNP)
● I in: 10 mA max.
(Load resister:
2.2kΩ or more)
● ON voltage: +24V
DC24V
Signal
GND
NC
ON
OFF