Status Of The Synchronized Actions; Commissioning - Siemens SINUMERIK 840Di sl Operating Manual

Hide thumbs Also See for SINUMERIK 840Di sl:
Table of Contents

Advertisement

4
01/2008

4.2.11 Status of the synchronized actions

Synchron.
actions
© Siemens AG 2008 All rights reserved.
SINUMERIK 840Di sl/840D sl/840D Operating Manual HMI-Advanced (BAD) - 01/2008 Edition
4.2
Function
Status information (such as "enabled", "disabled", etc.) can be
displayed here to support commissioning of synchronized actions.
References: /PGA/, Programming Guide Advanced, Chapter
"Synchronized actions"
Sequence of operations
"AUTO"/"MDA"/"JOG" mode is selected in the "Machine" operating
area.
Press the "ETC" key followed by
the "Synchroniz. actions" softkey.
The display "Status of synchronized actions" appears.
Status of synchronized actions
Current block
+ X
900.000 mm
0.000
+X900.000mm0.000
- Y
-156.000 mm
0.000
N100 X100
-Y-156.000mm0.000
N200 X200
+ Z
230.000 mm
0.000
+Z230.000mm0.000
N300 X0
Programmed synchronized actions
N100 Ids=1
N129 Ids=2
N100 ID=3
N1000
The display shows:
• "Current block" column:
Current section of selected part program:
Preceding, current and following block
• "Programmed synchronized actions" column:
The programmed synchronized actions are listed block by block
with block number (static/modal actions are listed together with the
number of the synchronized action)
Machine operating area
General functions and displays
Status
Block no. SPF
enabled
N111
disabled
enabled
4
Search in
program
4-105