8
Diagnostics operating area
8.4
Service displays
8.4.4 Systemressourcen anzeigen
Diagnostics
Service
displays
System-
resources
Stop
Start
8-412
Function
For the NC areas you can display the system resources (utilization
display) currently being used:
Net and gross runtimes of
• position controller,
• interpolator and
• preprocessing.
Sequence of operations
The "Diagnostics" operating area is selected.
Press the "Service displays" softkey then "System resources".
The "NC utilization" screen is displayed.
The following minimum/maximum total data for the servo, IPO cycle
and preprocessing are displayed:
•
Net runtime in ms
•
Gross runtime in ms
•
Level of the IPO buffer in percent
•
Total capacity utilization in percent
The display update can be halted with the "Stop" softkey, the
displayed values are updated again with the "Start" softkey.
SINUMERIK 840Di sl/840D sl/840D Operating Manual HMI-Advanced (BAD) - 01/2008 Edition
8
01/2008
© Siemens AG 2008 All rights reserved.