Code Description
2108 START INHIBIT
Sets the Start inhibit function on or off. The Start inhibit function ignores a pending start command in any of the
following situations (a new start command is required):
• A fault is reset.
• Run Enable activates while start command is active.
• Mode changes from local to remote.
• Mode changes from remote to local.
• Control switches from
• Control switches from
0 =
– Disables the Start inhibit function.
OFF
1 =
– Enables the Start inhibit function.
ON
2109 EM STOP SEL
Defines control of the Emergency stop command. When activated:
• Emergency stop decelerates the motor using the emergency stop ramp (parameter 2208 EM DEC TIME).
• Requires an external stop command and removal of the emergency stop command before drive can restart.
0 =
– Disables the Emergency stop function through digital inputs.
NOT SEL
1 =
1 – Defines digital input
DI
• Activating the digital input issues an Emergency stop command.
• De-activating the digital input removes the Emergency stop command.
2...6 =
2...
6 – Defines digital input
DI
DI
• See
1 above.
DI
-1 =
1(
) – Defines an inverted digital input
DI
INV
• De-activating the digital input issues an Emergency stop command.
• Activating the digital input removes the Emergency stop command.
-2...-6 =
2(
)...
DI
INV
DI
• See
1(
) above.
DI
INV
2110 TORQ BOOST CURR
Sets the maximum supplied current during torque boost.
• See parameter 2101 START FUNCTION.
1 to
2.
EXT
EXT
2 to
1.
EXT
EXT
1 as the control for Emergency stop command.
DI
2...
6 as the control for Emergency stop command.
DI
DI
6(
) – Defines an inverted digital input
INV
1 as the control for Emergency stop command.
DI
2...
6 as the control for Emergency stop command.
DI
DI
73