Operating The Drive - ABB ACS550-01 User Manual

Drive low voltage ac drives
Hide thumbs Also See for ACS550-01:
Table of Contents

Advertisement

ACS550 User's Manual
Rotating arrow (clockwise or counter
clockwise)
Rotating arrow blinking
Stationary arrow
• Upper right – shows the active reference.
Middle. Using parameter Group 34, the middle of the LCD display can be configured
to display:
• 3 parameter values
The default values depend on the parameter 9904
motor control mode value. If 9904 = 1, the display
shows parameters 0102 (
0105 (
(
OUTPUT FREQ
• A bar meter rather than one of the parameter values.
Bottom. The bottom of the LCD display shows:
• Lower corners – show the functions currently
assigned to the two soft keys.
• Lower middle – displays the current time (if
configured to show the time).

Operating the Drive

LOC/REM – The very first time the drive is powered up, it is in the remote control
(REM) mode, and is controlled from the Control Terminal Block X1.
To switch to local control (LOC) and control the drive using the control panel, press
and hold the
is displayed:
• Release the button while LOCAL CONTROL is displayed to set the panel
reference to the current external reference. The drive stops.
• Release the button when LOCAL, KEEP RUN is displayed, to copy the current
run/stop status and the reference from the user I/O.
To switch back to remote control (REM) press and hold the
REMOTE CONTROL is displayed.
Start/Stop – To start and stop the drive press the START and STOP buttons.
Shaft direction – To change the shaft direction press DIR (parameter 1003 must be
set to 3 (
Reference – To modify the reference (only possible if the display in the upper right
corner is in reverse video) press the UP or DOWN buttons (the reference changes
immediately).
– indicates the drive and motor rotation status as follows:
Control Panel Display
). If 9904 = 3, the display shows 0103
TORQUE
), 0104 (
CURRENT
LOC
button until first, LOCAL CONTROL, or later, LOCAL, KEEP RUN,
REM
)).
REQUEST
• Drive is running and at setpoint
• Shaft direction is forward
Drive is running but not at setpoint.
Drive is stopped.
), 0104 (
SPEED
CURRENT
), 0105 (
TORQUE
Significance
or reverse
),
)
LOC
button until
REM
27