Byte 3: Base Value For The Frequencies (Bv) - Siemens SIMATIC S5 Manual

Ip 267 stepper motor controller
Hide thumbs Also See for SIMATIC S5:
Table of Contents

Advertisement

Addressing and Programming
Bit 0 to 7:
You must enter a value for the multiplier TI between 1 and 255 in
byte 2 of the configuration message frame. The value "0" disables
pulse generation. During cold restart or on power up, the value "0"
for TI is entered in the PIQ.
a =
BV =
TI =
R =
4.1.5

Byte 3: Base Value for the Frequencies (BV)

Bit 0 to 2:
You can select the eight possible frequency ranges for BV with the
three bits FB 0 to FB 2. If you do not enter a value, the module has a
default value of BV = 800 Hz on cold restart or on power up.
Table 4-4. Selecting the Frequency Range
FB2
FB1
FB0
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
4-6
BV (Hz) * R
a (Hz/ms) =
4
0.032 ms
*
Frequency increase or decrease
Base value for the frequency ( Table 4-4.)
Multiplier for the time interval TI (1 to 255)
Reduction factor (1 or 0.1). This factor is determined
in the current positioning job.
Base value
Accel./decel.
(Hz)
(Hz/ms)
TI = 1 to 255
800
6250 to 24.5
400
3125 to 12.25
200
1560 to 6.12
80
625 to 2.45
40
312 to 1.22
20
156 to 0.61
8
62.5 to 0.25
4
31.2 to 0.12
TI
*
Max. freq.
Pulse dura-
in kHz where
tion µs)
V = 255
204
102
51
20.4
15
10.2
31
5.1
63
2.04
127
1.02
255
EWA 4NEB 812 6061-02a