IP 267
0025 M002 :A
F
105.2
0026
:JC =M003
0027
:S
F
105.2
0028
:S
F
105.7
0029
:L
KH 0110
002B
:T
QW
88
002C
:L
KH 1000
002E
:T
QW
90
002F
:BEU
0030
:
0031
:
0032 M003 :L
KB 0
0033
:T
FY
105
0034
:R
Q
89.4
0035
:R
Q
89.5
0036
:
0037
:BE
EWA 4NEB 812 6061-02a
Application Examples
THIRD APPROACH SECTION: FORW.
WITH LOW VELOCITY
IF THE REFERENCE POINT (LIMIT
SWITCH END) HAS BEEN FOUND,
RESET ALL AUXILIARY FLAGS
AND SWITCH ON "STOP" MODE.