Rear View - Lenovo thinksystem SR630 Maintenance Manual

Hide thumbs Also See for thinksystem SR630:
Table of Contents

Advertisement

Status
Color
On
Green
Blinking
Green
Off
None
3
System ID button with system ID LED
Use this system ID button and the blue system ID LED to visually locate the server. A system ID LED is also
located on the rear of the server. Each time you press the system ID button, the state of both the system ID
LEDs changes. The LEDs can be changed to on, blinking, or off. You can also use the Lenovo XClarity
Controller or a remote management program to change the state of the system ID LEDs to assist in visually
locating the server among other servers.
If the XClarity Controller USB connector is set to have both the USB 2.0 function and XClarity Controller
management function, you can press the system ID button for three seconds to switch between the two
functions.
4
System error LED
The system error LED helps you to determine if there are any system errors.
Status
Color
On
Yellow
Off
None

Rear view

The rear of the server provides access to several connectors and components, including the power supplies,
PCIe adapters, hot-swap drive bays, serial port, and Ethernet connectors.
• "Rear view of server models with three PCIe slots" on page 16
• "Rear view of server models with two PCIe slots" on page 18
• "Rear view of server models with two hot-swap drive bays and one PCIe slot" on page 19
Rear view of server models with three PCIe slots
The following illustration shows the rear view of server models with three PCIe slots. Depending on the
model, your server might look slightly different from the illustration below.
16
ThinkSystem SR630 Maintenance Manual
Description
The server is connected to a network.
The network is connected and active.
The server is disconnected from the network.
Description
An error has been detected on the server.
Causes might include but not limited to the
following errors:
• The temperature of the server reached
the non-critical temperature threshold.
• The voltage of the server reached the
non-critical voltage threshold.
• A fan has been detected to be running at
low speed.
• A hot-swap fan has been removed.
• The power supply has a critical error.
• The power supply is not connected to
the power.
The server is off or the server is on and is
working correctly.
Action
Check the event log to determine the exact
cause of the error.
For information about troubleshooting, see
"Troubleshooting by symptom" on page
146 .
None.

Advertisement

Table of Contents
loading

Table of Contents