Mitsubishi Electric R16MTCPU Programming Manual page 20

Hide thumbs Also See for R16MTCPU:
Table of Contents

Advertisement

■Machine No. representation
In the positioning dedicated signals, "m" in "M43904+32m", etc. indicates a value corresponding to machine No. as shown in
the following table.
Machine No.
1
2
3
4
• Calculate as follows for the device No. corresponding to each machine.
Ex.
For machine No.8 in MELSEC iQ-R Motion device assignment
M43904+32m ([St.2120] Machine error detection) M43904+327=M44128
D53168+128m ([Md.2020] Machine type)=M53168+287=D54064
Representation of device No. used in this manual
The "R" and "Q" beside the device No. of positioning dedicated signals such as "[Rq.1140] Stop command (R: M34480+32n/
Q: M3200+20n)" indicate the device No. for the device assignment methods shown below. When "R" and "Q" are not beside
the device No., the device No. is the same for both device assignment methods.
Symbol
R
Q
18
m
Machine No.
0
5
1
6
2
7
3
8
Device assignment method
MELSEC iQ-R Motion device assignment
Q series Motion compatible device assignment
m
4
5
6
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R64mtcpuMelsec iq-r seriesR32mtcpu