Precautions

CPU buffer memory address used in Motion dedicated instruction

Information corresponding to positioning dedicated signal is output to the system area on the CPU buffer memory (U3E\G0
to 2k points) of the Motion CPU. When executing Motion dedicated PLC instructions, interlock the signals of this area.
Start accept flag (System area)
The status of each flag is stored in the following address.
CPU buffer memory address
( ) is decimal address
204H(516)
205H(517)
206H(518)
207H(519)
20EH(526)
20FH(527)
210H(528)
211H(529)
2 MOTION DEDICATED PLC INSTRUCTION
82
2.3 Precautions
Description
The start accept flag for 64 axes are stored corresponding to each bit.
Bits are actually set as the following:
• R64MTCPU: J1 to J64
• R32MTCPU: J1 to J32
• R16MTCPU: J1 to J16
OFF: Start accept enable
ON: Start accept disable
b15
204H(516) address
J16
205H(517) address
J32
206H(518) address
J48
207H(519) address
J64
The command generation axis start accept flag for 64 axes are stored corresponding to each bit.
Bits are actually set as the following:
• R64MTCPU: J1 to J64
• R32MTCPU: J1 to J32
• R16MTCPU: J1 to J16
OFF: Start accept enable
ON: Start accept disable
b15
20EH(526) address
J16
20FH(527) address
J32
210H(528) address
J48
211H(529) address
J64
b2
b1
b0
J2
J1
J18
J17
J34
J33
J50
J49
b2
b1
b0
J2
J1
J18
J17
J34
J33
J50
J49