Cc-Link Ie Field Network Instructions - Mitsubishi Electric MELSEC iQ-R Series Programming Manual

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

3.4

CC-Link IE Field Network Instructions

Reading data from the intelligent device station/remote device station
Instruction symbol
Processing details
JP.REMFR
Reads data from the buffer memory area of the intelligent device station or the remote device
station in units of words (16-bit address specified).
ZP.REMFR
JP.REMFRD
Reads data from the buffer memory area of the intelligent device station or the remote device
station in units of words (32-bit address specified).
Writing data to the intelligent device station/remote device station
Instruction symbol
Processing details
JP.REMTO
Writes data to the buffer memory area of the intelligent device station or the remote device station
in units of words (16-bit address specified).
ZP.REMTO
JP.REMTOD
Writes data to the buffer memory area of the intelligent device station or the remote device station
in units of words (32-bit address specified).
Reading the module model information of an intelligent device station
Instruction symbol
Processing details
J.SINFTYRD
Reads the model names of modules and units used in an intelligent device station.
JP.SINFTYRD
G.SINFTYRD
GP.SINFTYRD
Reading the module status information of an intelligent device station
Instruction symbol
Processing details
J.SINFSTRD
Reads the status information of modules and units used in an intelligent device station.
JP.SINFSTRD
G.SINFSTRD
GP.SINFSTRD
Setting parameters
Instruction symbol
Processing details
G.CCPASET
Sets parameters to the master, submaster, and local stations.
Use the G(P).CCPASET instruction to set parameters in the following cases.
• To change parameters without resetting the CPU module
• To install more modules than can be set by the engineering tool
GP.CCPASET
Setting the station number to own station
Instruction symbol
Processing details
G.UINI
Sets the station number to the local station (own station).
Use the engineering tool or UINI instruction to set network parameters excluding the station
GP.UINI
number.
Z.UINI
ZP.UINI
Reference
Page 1600 JP.REMFR,
ZP.REMFR
Page 1610
JP.REMFRD
Reference
Page 1605 JP.REMTO,
ZP.REMTO
Page 1615
JP.REMTOD
Reference
Page 1620
J(P).SINFTYRD,
G(P)SINFTYRD
Reference
Page 1624
J(P).SINFSTRD,
G(P)SINFSTRD
Reference
Page 1629
G(P).CCPASET
Reference
Page 1635 G(P).UINI,
Z(P).UINI
3 MODULE DEDICATED INSTRUCTIONS
3.4 CC-Link IE Field Network Instructions
3
137