Device data
The following table lists devices and constants that can be used to specify the setting data of instructions.
Data type
Description
Bit
Bit data can be handled.
Page 40 Bit data
Word
Word data can be handled.
Page 42 16-bit data (word data)
16-bit signed binary
16-bit data can be handled.
The value range varies depending on whether the value is signed or unsigned.
16-bit unsigned binary
Page 42 16-bit data (word data)
Double word
Double-word data can be handled.
Page 45 32-bit data (double word data)
32-bit signed binary
Two consecutive sets of 32-bit data or 16-bit data can be handled.
The value range varies depending on whether the value is signed or unsigned.
32-bit unsigned binary
Page 45 32-bit data (double word data)
64-bit signed binary
Two consecutive sets of 64-bit data or 32-bit data can be handled.
The value range varies depending on whether the value is signed or unsigned.
64-bit unsigned binary
BCD 4-digit
BCD 4-digit data can be handled.
16-bit data is divided by 4 digits and each digit is specified in 0 to 9.
BCD 8-digit
BCD 8-digit data can be handled.
32-bit data is divided by 8 digits and each digit is specified in 0 to 9.
BCD 16-digit
BCD 16-digit data can be handled.
64-bit data is divided by 16 digits and each digit is specified in 0 to 9.
Single-precision real
Single-precision real number data (single-precision floating-point data) can be
number
handled.
Page 48 Configuration of single-precision real number data
Double-precision real
Double-precision real number data (double-precision floating-point data) can
number
be handled.
Page 49 Configuration of double-precision real number data
Character string
ASCII code and Shift JIS code character string data can be handled.
Page 51 String data
Unicode character string
Unicode character string data can be handled.
Page 51 String data
Device name
A device can be specified directly.
*1 A constant can be used in the data specified for the source (s) or numerical data (n) by an instruction.
*2 For the specification method, refer to the detail page of each data type.
*1
Specifiable device/constant
• Bit device
• Bit specification of word device
• Word device
• Digit-specified bit device (K1 to K4)
• Decimal constant
• Hexadecimal constant
• Word device
• Double-word device
• Digit-specified bit device (K1 to K8)
• Decimal constant
• Hexadecimal constant
• Word device
• Double-word device
• Decimal constant
• Hexadecimal constant
• Word device
• Digit-specified bit device (K1 to K4)
• Decimal constant
• Hexadecimal constant
• Word device
• Double-word device
• Digit-specified bit device (K1 to K8)
• Decimal constant
• Hexadecimal constant
• Word device
• Double-word device
• Decimal constant
• Hexadecimal constant
• Word device
• Double-word device
• Real constant
• Word device
• Double-word device
• Real constant
• Word device
• Character string constant
• Word device
• Character string constant
• Device name corresponding to applicable
device
1 OVERVIEW
1.2 Data Specification Method
1
*2
*2
*2
*2
37