Figure 88 Intra-domain multi-segment PW
CE 1
Inter-domain multi-segment PW
An inter-domain multi-segment PW has concatenated PWs in different ASs, and is a method for
inter-AS option B networking.
As shown in
different ASs, you can perform the following operations:
Concatenate PW 1 and PW 2 on ASBR 1.
Concatenate PW 2 and PW 3 on ASBR 2.
Figure 89 Inter-domain multi-segment PW
MPLS or IP backbone
AS 100
CE 1

VCCV

Virtual Circuit Connectivity Verification (VCCV) is an OAM feature for L2VPN. It verifies the
connectivity of PWs on the data plane. VCCV includes the following modes:
Manual mode—Use the ping mpls pw command to manually test the connectivity of a PW.
Auto mode—Configure BFD or Raw BFD to automatically test the connectivity of a PW.
For more information about VCCV, see
MPLS or IP backbone
PW 1
PE 1
Tunnel
PE 3
Figure
89, to create an inter-domain multi-segment PW between PE 1 and PE 2 in
ASBR 1
PW 2
PE 1
PW
PE 2
PW
PW 2
PE 4
MPLS or IP backbone
ASBR 2
PE 2
"Configuring MPLS
OAM."
329
CE 2
AS 200