Step
2.
Enter Layer 2 Ethernet
interface view or Layer 2
aggregate interface view.
3.
Create an Ethernet service
instance and enter Ethernet
service instance view.
4.
Bind the Ethernet service
instance to a VSI.
Configuring UPE dual homing
This task includes the following configurations:
•
Create a backup PW for the primary PW.
•
Specify whether to switch traffic from the backup PW to the primary PW when the primary PW
recovers, and set the wait time for the switchover.
•
Perform a manual PW switchover.
Configuring static PW redundancy
Step
1.
Enter system view.
2.
Enter VSI view.
3.
Specify static signaling for
PWs, and enter VSI static
view.
4.
(Optional.) Specify the
switchover mode and set the
wait time for the switchover.
5.
Configure a static PW and
enter VSI static PW view.
Command
•
Enter Layer 2 Ethernet interface
view:
interface interface-type
interface-number
•
Enter Layer 2 aggregate
interface view:
interface bridge-aggregation
interface-number
service-instance instance-id
xconnect vsi vsi-name
[ access-mode { ethernet | vlan } ]
[ track track-entry-number&<1-3> ]
Command
system-view
vsi vsi-name
pwsignaling static
revertive { wtr wtr-time | never }
peer ip-address [ pw-id pw-id ]
[ in-label label-value out-label
label-value ] [ no-split-horizon |
pw-class class-name |
tunnel-policy
tunnel-policy-name ] *
384
Remarks
N/A
By default, no Ethernet
service instances exist.
By default, an Ethernet service
instance is not bound to any
VSI.
Remarks
N/A
N/A
By default, no PW signaling
protocol is specified for the VSI.
By default, the switchover mode is
revertive and the switchover wait
time is 0 seconds.
By default, no static PWs exist.