Siemens SINUMERIK 840D sl Configuration Manual page 101

Sinumerik step 7 toolbox v14 sp1
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Assignment of the IO modules to the NCK machine data
MD10510 $MN_DPIO_LOGIC_ADDRESS_OUT[1]=1020
MD10511 $MN_DPIO_RANGE_LENGTH_OUT[0]=1
MD10511 $MN_DPIO_RANGE_LENGTH_OUT[1]=4
Further information
● General information concerning this machine data is available in Chapter A4 of the
SINUMERIK 840D sl Supplementary Functions Manual: Digital and analog NCK I/Os for
SINUMERIK 840D sl.
● Specific information on the individual machine data can be found in the online help of
SINUMERIK Operate.
SINUMERIK STEP 7 Toolbox V14 SP1
Configuration Manual, 05/2017, A5E41846325
Configuring networks
4.5 Configuring PROFINET IO with IRT