Unique PROFIsafe addresses
You must ensure the unique assignment of the PROFIsafe address throughout the network
and the CPU.
• The fail-safe I/O of PROFIsafe address type 1 is addressed clearly by its fail-safe
• The fail-safe destination address of the fail-safe I/O (drive units in this case) must be
• Note also the corresponding documentation in the TIA Portal online help in Section
Acceptance of the system
Information on the acceptance of a safety configuration with controller can be found in the
TIA Portal information system under "Acceptance of the system".
Note
Error-free hardware and software transmission
Error-free HW and SW transmission is the prerequisite for the creation of the safety printout
for acceptance purposes. Only then is it assured that all consistency checks have been
performed and therefore the safety printout created for a consistent project.
SINUMERIK STEP 7 Toolbox V14 SP1
Configuration Manual, 05/2017, A5E41846325
WARNING
destination address.
unique for the entire fail-safe I/O throughout the network and the CPU (system-wide).
The fail-safe I/O of PROFIsafe address type 2, e.g. modules of the ET 200SP type, must
also be taken into account.
"SIMATIC Safety - Configuration and programming".
SIN001
(
)
9.8 Configuring Safety Integrated plus (F-PLC)
Safety configuration
199