Basic Functions; Learn Run - Siemens SIDOOR ATD401W System Manual

Atd4xxw series, door control systems for industrial applications
Hide thumbs Also See for SIDOOR ATD401W:
Table of Contents

Advertisement

3.1

Basic functions

Introduction
You will also need the basic functions described below to use a SIDOOR door controller.
3.1.1

Learn run

Description of function
The following system properties are determined and stored with a learn run:
● Door width
● Effective door weight and counterweight
● Door friction
● Direction of rotation of the motor and pulse encoder
As of V1.10: As an alternative to the learn run, the basic parameters determined during the
learn run can be configured using the basic parameters editor. This allows initial
commissioning of the SIDOOR door controller without a learn run (see section "Basic
parameters editor (Page 83)").
Note
For the motors M4, MDG400, MDG400 NMS, M5 and MDG700 NMS, the output
transmission (Page 38) must be checked before each learn run and adjusted if necessary.
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB
SIDOOR functions
3.1 Basic functions
29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sidoor atd420wSidoor atd410wSidoor atd430w

Table of Contents