3.4.1.3

Pressure-sensitive edge (SR)

Function description
The pressure-sensitive edge is connected to the machine control and assumes a defined
state if the sensor device is addressed during proper operation.
Connection and parameter assignment
The output signal switching device of the pressure-sensitive edge is connected to "Input 1" of
the terminal X6.
If the SIDOOR controller's sensor logic is configured for a pressure-sensitive edge, the
"TestOUT" function test signal is output automatically at the terminal X100.1. See Section
Sensor function test (Page 155).
The sensor type of the sensor connected to "Input 1" of terminal X6 can be configured as
follows:
● Parameter p4600
● Service menu:
The travel range before the "Closed" position in which the controller responds to the
pressure-sensitive edge's signal can be restricted by parameter p1210 (see Section
Calibration and function parameters (Page 179)). The controller does not respond to the
pressure-sensitive edge's signal in the range of ± 2 cm before the "Open" position.
Note
The DCOPS, type 2 ESPE or pressure-sensitive edge functions cannot be implemented
simultaneously as sensor functions at input 1.
You will find a circuit diagram and detailed information about connection of a pressure-
sensitive edge in Section Overview (Page 152).
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB
MAIN MENU > General setup > Special parameters > Function Input 1
SIDOOR functions
3.4 Safety functions
89