A.2

Profiles and adjustment ranges

A.2.1

Profile name

Profile
1
A.2.2

SIDOOR M3 L / R

Table A- 42
Parameters and adjustment range SIDOOR M3 L / R apply for the SIDOOR ATD4xxW controller
Parameter
Slow end distance open
Slow start distance open
Slow start distance close
Slow end distance close
Maximum speed open
Slow end speed open
Slow start speed open
Slow initial speed open
Maximum speed close
Slow start speed close
Slow end speed close
Slow initial speed close
NDG speed (reduced)
Acceleration ramp open
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB
M3 R / L
MDG180 R / L
M3 default profile
Parameter ID
Unit
p3660
mm
p3661
mm
p3662
mm
p3663
mm
p3664
mm/s
p3665
mm/s
p3666
mm/s
p3667
mm/s
p3668
mm/s
p3669
mm/s
p3670
mm/s
p3671
mm/s
p3672
mm/s
p3673
mm/s
A.2 Profiles and adjustment ranges
SIDOOR ...
M4 R / L
MDG400 R / L
MDG400NMS R / L
M4 default profile
Profile 1*
30
30
20
40
650
40
60
90
281
60
40
90
281
1300
2
Appendices
M5 R / L
M5 default profile
Adjustment range
ATD4xxW
0 ... 100
0 ... 100
0 ... 100
0 ... 100
100 ... 650
30 ... 650 (as of
V1.03)
30 ... 90
30 ... 90
30 ... 90
100 ... 650
30 ... 650 (as of
V1.03)
30 ... 90
30 ... 90
30 ... 90
50 ... 650
30 ... 650 (as of
V1.03)
300 ... 1400
As of (V1.09): 250 ...
1400