8.2

PROFIBUS integration via GSD file

Install the GSD file (see Industry Online Support
(http://support.automation.siemens.com/WW/view/en/61054703/133200)) in the applicable
configuration tool before configuring the SIDOOR ATD420W PROFIBUS controller.
After installation, you will find the ATD420W controller under the following category:
"PROFIBUS DP > Further field devices > Drives > SIDOOR"
Note
When configuring the device, ensure that the input and output addresses both start with the
same value.
When the system is configured, the device parameters are automatically assigned the
following default values specified by the GSD.
● Data exchange: "Enabled"
● Baud rate: "115200"
● Slave address: "0"
● Frame type: "Standard telegram"
● Cycle time [ms]: "100"
You can find additional information in the section PROFIBUS module (Page 121).
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB
Configuration and programming in STEP 7
8.2 PROFIBUS integration via GSD file