Zsw1 - Status Word (Statw) - Siemens SIDOOR ATD401W System Manual

Atd4xxw series, door control systems for industrial applications
Hide thumbs Also See for SIDOOR ATD401W:
Table of Contents

Advertisement

Appendices
A.1 Structure of user data/process data
A.1.2.5

ZSW1 - status word (StatW)

Status word 1 (ZSW1) is identical to the specification in the PROFIBUS profile "Variable-
speed drives".
Bits 0 to 10 correspond exactly to the specifications for the PROFIBUS profile "Variable-
speed drives". The use and non-use of specific bits is marked accordingly.
The table below describes the assignments of the bits in status word 1.
Table A- 21
Bit
0
1
2
3
4
5
6
7
8
9
10
11 ... 15
290
Status word 1 (ZSW1)
Description
Ready for switching on
Ready
Operation enabled
Fault active
No OFF2 (no coast down)
No OFF3 (no rapid stop)
Switch-on inhibit
Reserved
Reserved
Control requested by PLC
Reserved
Reserved
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB